Yokogawa AIP502 V-Net Coupler Module for CENTUM CS/VP

The Yokogawa AIP502 is a V-Net Coupler Module designed for Yokogawa's CENTUM CS and CENTUM VP distributed control systems (DCS). It serves as the communication interface between various components within the V-Net control network, enabling high-speed data exchange between Field Control Units (FCUs), operator stations, and other DCS devices.

  • Item nº :

    AIP502
  • Pedido (MOQ) :

    1
  • Pagamento :

    EXW
  • Origem do produto :

    Japan
  • Porto de embarque :

    Wuhan, Hubei, China
  • Tempo de espera :

    3-5 days
  • Peso :

    3kg
  • PRODUCT INFORMATIOM

    AIP502 V-Net Coupler Module

    Brand Name: Yokogawa Condition: 100%New And Original
    Product Name: AIP502 Warranty: 1Year
    MOQ: 1Piece Packing: Original Packing

     

    OVERVIEW

    The Yokogawa DCS MODULE is an input/output module designed by Yokogawa for its CENTUM series of distributed control systems (DCS).

    These modules offer high performance and a wide range of functions to meet the needs of a wide range of control systems. As an important part

    of the CENTUM system, Yokogawa DCS MODULE plays a key role in the field of industrial automation and process control.

     

    WHY CHOOSE US

    Customers

    Our products have been sold to around the worlds. 

    Price

    Industry leading price ,Compare&Save for customers. 

    Wide selection

    All 100% brand new industrial products with large inventory for your selection.

     

     

    PACKING

    Professionalism: Our experienced team ensures that your goods are handled with care and expertise throughout the packaging process.

    Environmental Friendliness: We prioritize sustainable practices, using eco-friendly materials and methods that minimize environmental impact.

    Convenience: Our packaging services are designed to be hassle-free for you. We offer flexible options tailored to your specific needs and requirements.

    Efficiency: With streamlined processes and attention to detail, we ensure efficient packaging that meets deadlines without compromising on quality.

    FAQ

    Q1: What is the Yokogawa AIP502 used for?
    According to the most consistent sources, it is a V-Net Coupler Module for Yokogawa CENTUM CS/VP DCS systems, providing the communication interface between components on the V-Net control network .

    Q2: What are the exact specifications?
    Official Yokogawa datasheet is not available in the search results. Third-party sources provide conflicting data (dimensions, weight, operating temperature, and safety certifications). You must obtain the official Yokogawa datasheet for the exact order variant before making any decision.

    Q3: What is the difference between AIP502 and AIP512?
    The AIP512 (documented in a previous response) is a RIO Bus Connection Module. The AIP502 is a V-Net Coupler Module. They serve different network layers in the CENTUM architecture. Verify exact compatibility with your system design.

    Q4: What is the S1 suffix?
    The S1 designation indicates the Style S1 hardware revision. This appears consistently across credible listings for the AIP502 .

    Q5: What is the power supply requirement?
    The most credible sources cite 24 VDC . Verify this against official documentation.

    Q6: Is the AIP502 a PLC module or a DCS coupler?
    Sources conflict. Some describe it as a PLC module with Modbus/DeviceNet or an FA-M3 analog input module . The majority of credible sources describe it as a V-Net Coupler for CENTUM DCS . Verify with Yokogawa.

    Q7: Is this a current or legacy product?
    The AIP502 is associated with CENTUM CS/VP systems, which are mature platforms. Confirm current product status and availability with Yokogawa or an authorized distributor.

    Q8: Where can I get technical documentation?
    Official Yokogawa documentation is essential. The third-party search results are unreliable and contradictory. Contact Yokogawa or an authorized distributor directly for the datasheet matching your exact order number.


    Recommending Models

     
     
    Model Description When to Choose
    AIP502 V-Net Coupler Module (Style S1) for CENTUM CS/VP When replacing or stocking spares for existing CENTUM installations (confirm exact variant and availability)
    AIP512 RIO Bus Connection Module for CENTUM CS 3000/VP When a RIO bus interface is required instead of a V-Net coupler (confirm differences with Yokogawa)
    AIP511 Older V-Net coupler module When an older CENTUM system requires a compatible predecessor (confirm with Yokogawa)
    Newer CENTUM VP modules Current-generation V-Net/RIO interface modules When a current-production replacement is required for new installations or upgrades (consult Yokogawa)

     

Deixe um recado